Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Chinese Journal of Ultrasonography ; (12): 625-630, 2021.
Article in Chinese | WPRIM | ID: wpr-910102

ABSTRACT

Objective:To compare the values of medical image technologies in evaluating the tansperineal laser ablation (TPLA) in canine prostate.Methods:TPLA (3 W/600 J and 3 W/1 200 J) were operated in the prostate of six adult male beagles guided by transrectal ultrasound (TRUS). TRUS, transrectal contrast-enhanced ultrasound (TR-CEUS) and multiparameter magnetic resonance imaging (mpMRI) were used to evaluate the ablation on the day of TPLA, one week and one month after TPLA. The animals were sacrificed for pathology to calculate the volume of the ablation. SPSS 22.0 software was used for statistical analysis.Results:TRUS could be used to guide and observe the puncture and ablation process during TPLA. TR-CEUS and contrast enhanced MRI showed good consistency in the volume of ablation ( P>0.05). One month after TPLA, the ablation volume were (1.69±0.51)ml vs (1.73±0.36)ml vs (1.52±0.41)ml (3 W/600 J) and (2.23±0.54)ml vs (2.34±0.29)ml vs (2.19±0.34)ml (3 W/1 200 J) measured by the two medical image technologies and pathology, with good consistency ( P>0.05). Conclusions:TRUS can be used to guide and observe the puncture and ablation process during TPLA. TR-CEUS and mpMRI can be used for postoperative evaluation and follow-up of TPLA. The former has advantages of real-time and low price, which can be promoted and applied in clinical practice.

2.
Chinese Journal of Ultrasonography ; (12): 807-811, 2020.
Article in Chinese | WPRIM | ID: wpr-868085

ABSTRACT

Objective:To prepare ultrasound-responsive nanodroplets with block polymer PEG-PCL as shell and perfluoropentane (PFP) as core, and study the effects of mechanical index (MI) on contrast-enhanced imaging properties of nanodroplet.Methods:PEG-PCL micelles were first prepared by dialysis, and then the micelles were mixed with PFP for emulsification to obtain nanodroplets. The particle size and zeta potential of nanodroplets were measured, and the morphology of nanodroplets were observed using transmission electron microscope (TEM). The stability of nanodroplets after storage at 25 ℃ and 37 ℃ was investigated. The phase transition and contrast-enhanced imaging of nanodroplets in vitro under a series of mechanical index (MI) were studied using an ultrasound diagnostic instrument.Results:The particle size of the nanodroplets was (356.6±5.6)nm, and the zeta potential was -(7.30±0.14)mV. The nanodroplets were close to spherical under TEM and had a clear core-shell structure. The particle size and dispersion of the nanodroplets increased after storage at 37 ℃ and 25 ℃. For imaging in vitro, no acoustic signal were observed at 25 ℃ when the MI varied from 0.08 to 1.0. At 37 ℃, acoustic signals were observed when MI≥0.4, and the intensity was stronger for higher MIs.Conclusions:The contrast-enhanced imaging of nanodroplets are closely related to the MI, and a higher MI could induce the phase transition of more nanodroplets and produce stronger contrast enhancement. This study could provide basis for the application of polymeric nanodroplets in ultrasound diagnosis and targeted therapy.

3.
Chinese Journal of Ultrasonography ; (12): 283-288, 2019.
Article in Chinese | WPRIM | ID: wpr-754799

ABSTRACT

Objective To investigate the clinical application value of longitudinal peak strain( LPS ) and peak strain dispersion ( PSD ) in evaluating left ventricular systolic function and synchrony in patients with essential hypertension . Methods Fifty‐five patients with essential hypertension were enrolled , including 30 patients with non‐left ventricular hypertrophy ( NLV H ) , 25 patients with left ventricular hypertrophy ( LV H ) , at the same time , 30 healthy volunteers were selected as the control group . Echocardiography was performed in all three groups ,and two‐dimensional dynamic images of the left ventricular apical four‐chamber ,three‐chamber ,and two‐chamber′s long‐axis view s were collected for three consecutive cardiac cycles . T he myocardial layer‐specific strain was used to measure the LPS of the left ventricular myocardium of subendocardium ,the middle layer ,the subepicardium ,and the myocardial strain and the PSD of the w hole myocardial layers . Correlation analysis and ROC curve analysis were performed . Results T he LPS in the control group ,NLV H group and LV H group were decreased in turn from inner to out myocardial layers . Compared with the control group , the LPS in the subendocardial , middle , subepicardial ,and w hole myocardial layer of NLV H group were decreased ( P < 0 .05 ) , and the subepicardial myocardial LPS was slightly lower than that in the control group ,the difference was not statistically significant ( P > 0 .05 ) . T he LPS in the subendocardial , middle , subepicardial ,and whole myocardial layer of LV H group were all reduced ( P<0 .05) . Between the NLV H group and LV H group , the declines of the LPS in the subendocardial and middle layer in the LV H group were statistically significant ( P <0 .05) ,the LPS in the subepicardial layer and the w hole myocardial layer had no significant difference ( P >0 .05) . Compared with the control group ,the PSD of the NLVH group and the LVH group increased ( P < 0 .05 ) . Compared with the NLV H group ,the PSD of the LV H group increased ( P <0 .05) . Inter‐ventricular septum thickness ( IVSd) and the LPS in the subendocardial ,middle ,subepicardial , and w hole myocardial layer were negatively correlated ( r = -0 .537 ,-0 .518 ,-0 .266 ,-0 .471 ; all P <0 .05) , left ventricle posterior wall thickness ( LVPWd ) and the LPS in the subendocardial , middle , subepicardial ,and whole myocardial layer were negatively correlated ( r = -0 .539 , -0 .524 , -0 .283 ,-0 .478 ;all P <0 .05) . T he area under the ROC curve ( AUC) of the LPS in the subendocardial ,middle , subepicardial ,and w hole myocardial layer and PSD for the diagnosis of hypertension were 0 .685 ,0 .652 , 0 .510 ,0 .623 ,0 .995 ,respectively . T he cut‐off values were -21 .70% ,-18 .90% ,-16 .95% ,-19 .45% , 46 .50 ms , and the sensitivities were 94 .4% , 83 .3% , 77 .8% , 94 .4% , 100% , respectively , and the specificities were 47 .8% ,52 .2% ,39 .1% ,39 .1% ,95 .7% ,respectively . Conclusions T he layer‐specific strain can quantitatively evaluate myocardial longitudinal strain in patients with essential hypertension , provide a non‐invasive test for early diagnosis of hypertensive heart disease ,and the evaluation of left ventricular myocardial stratification . PSD for evaluating primary synchronous changes in left ventricular myocardial contraction in patients with hypertension has certain advantages .

4.
Chinese Journal of Ultrasonography ; (12): 569-573, 2018.
Article in Chinese | WPRIM | ID: wpr-806977

ABSTRACT

Objective@#To quantitatively evaluate the variation of preoperative and postoperative structure and function of mitral valve after mitral valve annuloplasty(MVP) for mitral valve prolapse by real-time three-dimensional transesophageal echocardiography(RT-3D TEE).@*Methods@#Thirty patients with mitral valve prolapse for MVP were studied, the minimum area of the three-dimensional view of the annulus(A3Dmin), three dimensional circumference(C3D), anterolateal-to-posteromedial diameter(DAlPm), anterior-to-posteior diameter(DAP), height (H), the ratio of annulus height to anterolated-to-posteromedial diameter(H/DAlPm), aorto-mitral angle(θ), the ellipticity of the the anterior-to-posterior diameter and anterolateal-to-posteromedial diameter of the annulus(E2D), the three-dimensional exposed area of the leaflet(A3DE), prolapse height(HProl), prolapse volume(VProl), non-planarity angle(θNPA) were evaluated by RT-3D TEE before and after operation. Coaptation area(CoapA), coaptation index(CPI), annulus systolic function index were calculated.@*Results@#Compared with the preoperation, A3Dmin, C3D, DAlPm, DAP, H, H/DAlPm, A3DE, HProl, VProl, θNPA of postoperative were reduced, E2D, CoapA, CPI, annulus systolic function index of the postoperation increased, the difference of above parameters were statistically significant (P<0.05). CPI and annulus systolic function index were negatively correlated with the area of valve regurgitation area before and aftere operation (r=-0.79, P<0.01; r=-0.67, P<0.01). Furthermore, CPI was closely correlated with annulus systolic function index (r=0.63, P<0.01).@*Conclusions@#After MPV, mitral valve three-dimensional structural parameters are significantly changed, CPI and annulus systolic function are improved. CPI is closely correlated with annulus systolic function, and RT-3D TEE can quantitatively evaluate the structure and function of mitral valve before and after MPV.

5.
Genomics, Proteomics & Bioinformatics ; (4): 428-438, 2018.
Article in English | WPRIM | ID: wpr-772974

ABSTRACT

DNA damage response (DDR) is essential for maintaining genome stability and protecting cells from tumorigenesis. Ubiquitin and ubiquitin-like modifications play an important role in DDR, from signaling DNA damage to mediating DNA repair. In this report, we found that the E3 ligase ring finger protein 126 (RNF126) was recruited to UV laser micro-irradiation-induced stripes in a RNF8-dependent manner. RNF126 directly interacted with and ubiquitinated another E3 ligase, RNF168. Overexpression of wild type RNF126, but not catalytically-inactive mutant RNF126 (CC229/232AA), diminished ubiquitination of H2A histone family member X (H2AX), and subsequent bleomycin-induced focus formation of total ubiquitin FK2, TP53-binding protein 1 (53BP1), and receptor-associated protein 80 (RAP80). Interestingly, both RNF126 overexpression and RNF126 downregulation compromised homologous recombination (HR)-mediated repair of DNA double-strand breaks (DSBs). Taken together, our findings demonstrate that RNF126 negatively regulates RNF168 function in DDR and its appropriate cellular expression levels are essential for HR-mediated DSB repair.


Subject(s)
Humans , Carrier Proteins , Metabolism , Cell Line, Tumor , DNA Breaks, Double-Stranded , DNA Repair , Genetics , DNA-Binding Proteins , Metabolism , Genomic Instability , HeLa Cells , Histones , Metabolism , Nuclear Proteins , Metabolism , RNA Interference , RNA, Small Interfering , Genetics , Signal Transduction , Tumor Suppressor p53-Binding Protein 1 , Metabolism , Ubiquitin , Ubiquitin-Protein Ligases , Genetics , Metabolism , Ubiquitination
6.
China Pharmacist ; (12): 978-980, 2015.
Article in Chinese | WPRIM | ID: wpr-669800

ABSTRACT

Objective:To compare the pharmacoeconomics value of domestic olanzapine with imported olanzapine in the treatment of schizophrenia to provide reference for the rational drug use in clinics. Methods:Two hundred patients with schizophrenia were ran-domly divided into group A ( treated with domestic olanzapine ) and group B ( treated with imported olanzapine ) with 100 cases in each. The treatment course was 8 weeks. The patient’ s condition, adverse reactions, social function, quality of life and daily activity in the two groups were evaluated. Meanwhile, cost-efficacy analysis was performed. Results:The scores of PANSS, SDSS, SQLS and ADL after the treatment were all significantly lower than those before the treatment in both groups (P0. 05). In the 2nd and 4th weekend after the treatment, the scores of TESS in group A were all significantly higher than those in group B (P<0. 01). The effectiveness of the two groups was similar. The cost in group A was significantly lower than that in group B(P<0. 01). The efficacy-cost ratio in group A was higher than that in group B(P<0. 01). Conclusion:The domestic olanzapine is as effective and safe as imported olanzapine in the treatment of schizophrenia with lower treat-ment cost. Therefore, the pharmacoeconomics value of domestic olanzapine is much better.

7.
Chinese Journal of Ultrasonography ; (12): 1031-1034, 2012.
Article in Chinese | WPRIM | ID: wpr-430019

ABSTRACT

Objective To study the relationship of the antepartum foramen ovale (FO),the ratios of foramen ovale and aorta (FO/AO) and postpartum ostium secundum atrial septal defect (ASD).Methods Nine hundred fifty-eight fetuses were divided into 5 groups by gestational age,18-22 weeks,23-26 weeks,27-30 weeks,31-34 weeks,35-40 weeks.The diameter of FO and aortic (AO) and FO/AO were measured by fetal echocardiography,the postpartum echocardiography were followed up more than 12 months after birth.ANOVA was used to compare FO,AO,FO/AO with different gestational age.Regression equation estimate was used to compare the relationship of FO and AO with gestational age.Independent sample T test was used to compare FO and FO/AO with postpartum ostium secundum ASD and postpartum normal heart.Results There was significant difference in FO and AO among 5 groups(P =0.000),FO and AO increased with increasing gestational age.There was significant difference in antepartum FO,FO/AO between postpartum ostium secundum ASD and postpartum normal heart (P =0.000).Conclusions Antepartum FO and FO/AO provide clinical value in observing postpartum ostium secundum ASD.

8.
Chinese Journal of Ultrasonography ; (12): 838-841, 2012.
Article in Chinese | WPRIM | ID: wpr-423570

ABSTRACT

Objective To evaluate the diagnostic accuracy of two dimensional echocardiography combining with enhanced flow (e-flow) imaging for fetal heart malformation.Methods 1580 cases were screened for fetal heart malformation.The diagnostic accuracy was evaluated by comparing the results fetal echocardiography with those of postpartum echocardiography,surgery or autopsy.Results Antepartum and postpartum data were obtained in 1286 of the 1580 fetuses (81.39%).Among the 1286 cases,the sensitivity,specificity,mistake diagnostic rate,omission diagnostic rate was 98.0 %,99.3 %,2.0 %,0.7%,respectively.The consistency evaluation of fetal heart malformation by two dimensional echocardiography combining with e-flow concluded that the valve of Kappa was 0.970 (P =0.000).Conclusions Two dimensional echocardiography combining with e-flow is an accurate and reliable method for diagnosing fetal heart malformation,it has a high sensitivity and specificity.

9.
Chinese Journal of Ultrasonography ; (12): 291-293, 2009.
Article in Chinese | WPRIM | ID: wpr-395347

ABSTRACT

Objective To assess the left ventricular synchronization and global systolic function in patients with implanted dual-chamber (DDD) mode cardiac pacemakers by real-time three-dimensional echocardiography(RT-3DE). Methods Left ventricular systolic synchronization and global function were evaluated in 20 patients with implanted DDD mode cardiac pacemakers and 20 normal people by RT-3DE. The left ventricular end-diastolic volume (LEDV), end-systolic volume ( LESV), stroke volume (SV), left ventricular ejection fraction (LVEF), the mean value of time from the start of electrocardiographic QRS wave to the point of minimal systolic volume (Tmean) of the 17 segments and those standard deviation(T-SD),the maximal difference of time among all 17 segments(Tmax) were obtained by RT-3DE. Results Compared with control group, LESV was significantly increased,SV, LVEF were significantly decreased and T-SD,Tmax were significantly prolonged (P <0.01 ). There were no differences in LEDV and Tmean between the two groups (P>0.05). In patients group,LVEF correlated closely with T-SD (r =-0.674, P<0.05) and Tmax (r = - 0. 634, P < 0. 05). Conclusions There were left ventrieular systolic asychronization and global systolic dysfunction in patients with implanted dual-chamber (DDD) mode cardiac pacemakers,which could be assessed by RT-3DE.

10.
Chinese Journal of Ultrasonography ; (12): 560-563, 2008.
Article in Chinese | WPRIM | ID: wpr-399486

ABSTRACT

Objective To detect the clinical value of evaluating myocardial viability in patients with old myocardial infaretion(OMI) by measuring myocardial isovolumie contraction motion indices with tissue Doppler imaging(TDI) under the quiescent condition. Methods The myocardial isovolumic contraction motion indices of 30 normal subjects and 30 patients with OMI were examined by TDI. The sample gate was located at left ventricular postero-septal,lateral,anterior,inferior,antero-septal and posterior walls in basal and middle segments separately. The peak positive and negative veiocities(VIVC1 ,VIVC2 ) during myocardial isovohimic contraction phase, and the difference(DIVC) between VIVC1 and VIVC2 were measured, which were analysed combined with the viable fraction(VF) calculated by single photon emission computed tomography (SPECT). Results VIVC1, DIVC were significantly decreased,and VIVC2 was significantly increased in infarct zones of patients with OMI than those of the normal subjects( P <0.05). Compared with normal subjects, myocardial isovolumic contraction motion indices of non-infarct wails in patients with OMI were steady( P >0.05). In OMI group,DIVC of short axis was significantly decreased than that in long axis( P <0.05). Statistic analysis showed that DIVC values on both of short and long axis had significant positive correlations with VF derived from SPECT,and the correlation coefficients were 0. 837 ( P<0. 001) and 0. 797( P<0. 001 ) ,respectively. The sensibility and specificity of evaluating viable myocardium was 75% and 75% separately supposing the cutoff of DIVC on short axis was more than - 1.50,and the sensibility and specificity was 77. 8% and 87.5% separately if the cutoff of DIVC on long axis was more than 0.92. Conclusions Myocardial isovolumic contraction's TDI of infarct zones in patients with OMI had characteristic changes. DIVC on both of short and long axis could be as a new method of evaluating myocardial viability.

11.
Chinese Journal of Ultrasonography ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-544020

ABSTRACT

Objective To assess the velocity patterns of right ventricular long axis myocardial motion during isovolumic contraction phase in the patients with dilated cardiomyopathy(DCM) by Doppler tissue imaging(DTI).Methods Right ventricular systolic free wall myocardial(the place close to the tricuspid annular) motion velocities were examined by DTI on apical four-chamber view in 28 patients with DCM and 30 healthy volunteers.Peak positive and negative velocities(V_(IVC1),V_(IVC2)),velocity time integrals(VTI_(IVC1),VTI_(IVC2)),times(T_(IVC1),T_(IVC2)) of right ventricular free wall myocardial motion during isovolumic contraction,and the peak velocity(V_S),time(T_S),velocity time integral(VTI_S) of ejection wave(S) were measured.Right ventricular percent changes in area(RVPCA) on three different views were calculated.Results V_(IVC1),V_S,VTI_S and differential IVC(the difference between V_(IVC1) and V_(IVC2)) in the patients with DCM were significantly decreased than those in control group(P(0.05)).Conclusions The changes of DTI indices of right ventricular long axis myocardial motion during isovolumic contraction in the patients with DCM are characteristic,which could be a new method to evaluate right ventricular systolic function.

SELECTION OF CITATIONS
SEARCH DETAIL